800.882.4266 • www.trinia.us
TRINIA™ Zr O2 Cr-Co
Tensile Strength 380 MPa 348 MPa 695 MPa
FlexuralStrength 540 MPa 1200 MPa 600 MPa
Flexural Modulus of Elasticity 26 GPa 210 GPa 275 GPa
CompressiveStrength 530 MPa 2000 MPa 448 MPa
Density 1. 8 g/cm3 >7g/cm3 8. 3 g/cm3
Resilience 300 KJ/cm2 - -
Fixed Prosthesis Bonded to Metal-Free TRINIA™ Bar
Four 4.0 x 5.0mm SHORT® Implants
The solution for metal-free CAD/CAM dental prosthetics.
Metal-Free Bars, Copings, Bridges,
and Telescopic Restorations
NEW! Next Generation of Fiber-Reinforced
CAD/CAM Restorations
● ● Durable, resilient, and lightweight
; ● Clinically forgiving
; ● Remarkably versatile
; ● Precise milling
The metal-free dental CAD/CAM solution
TRINIA™
LIT BB DE TRINIA-28Y 0913
Visit www.bicon.com/edu or call 800.88.BICON to register.
2013 SURGICAL AND PROS ThE TIC PRINCIPLES COURSES
Boston, MA 11/13–11/15
2013 hANDS-ON PRACTICAL COURSES
Boston, MA 9/6 | Los Angeles, CA 10/17 | San Francisco, CA 10/18
Boston, MA 12/6 | Atlanta, GA 12/12 | Orlando, FL 12/13
4.0 x 5.0mm
4.0 x 6.0mm
5.0 x 5.0mm
6.0 x 6.0mm
6.0 x 5.0mm
5.0x6.0mm 4.5x6.0mm
20 YEARS
18 YEARS
20 YEARS
5.0 x 6.0mm
5.0 x 6.0mm5.0 x 6.0mm
5.0 x 6.0mm
5.0 x 5.0mm
4.5x6.0mm 5.0x5.0mm
6.0 x 5.7mm
THE BICON DESIGN is driven by simplicity. A cornerstone of its
simplicity is SHORT® Implants. When the Bicon system was frst
introduced in 1985, its 8.0mm length implants were considered quite
short—most other implants were at least 12–14mm and sometimes
18–20mm long! Since then, the natural progression of Bicon’s design
philosophy has resulted in 5.0mm, 5.7mm, and 6.0mm SHORT®
Implants, all with YEARS of proven clinical success.www.bicon.com
PLATEAU DESIGN
Coelho, P.G., Bonfante E.A., Marin C., Granato R., Giro, G., Suzuki, M., Human Retrieval Study of
Plasma-sprayed Hydroxyapatite-Coated Plateau Root Form Implants After 2 Months to 13 Years in
Function, Journal of Long-Term Efects of Medical Implants, 2010; 20( 4):335-342.
Coelho, P.G., Granato, R., Marin, C., Bonfante, E.A., Janal, M.N., Sukuki, M., Biomechanical and Bone
Histomorphologic Evaluation of Four Surfaces on Plateau Root Form Implants: An Experimental
Study in Dogs, Oral Surg Med Oral Pathol Oral Radiol Endod 2010 May; 109( 5):e39-45.
Baldassarri, M., Bonfante, E.A., Suzuki, M., Marin, C., Granato, R.,Tovar, N., Coelho, P.G., Mechanical
Properties of Human Bone Surrounding Plateau Root Form Implants Retrieved After 0. 3–24 Years
of Function, J Biomed Mater Res B Appl Biomater, 2012 October;100B( 7):2015-2021.
3 Directbonetoimplantcontact
and multiple haversian systems
throughout
3 Confgurationsdenotehigh
mechanical properties as in
cortical bone
20 Years in Function 23 Years in Function
18 Years in Function
BONE GAIN
Urdaneta, R.A., Daher, S., Leary J., Emanuel K., Chuang, S.K., Tovar, L.A.,
Factors Associated with Crestal Bone Gain on Single-Tooth Locking-Taper Implants: The Efect
of NSAIDs, Int J Oral Maxillofac Implants 2011;26:1063-1078
2003 2012
2006 2010
6.0 x 5.7mm
14 YEARS
6.0 x 5.7mm
7 YEARS